EVI air source heat pump 2018-05-03T08:48:45+00:00

EVI air source heat pump – low temp work -25℃
work at -25℃ ambient temp
max outlet hot water temp +60℃
for sanitary hot water and under floor heating

heat pump for low temp CAR-12EVI
  • EVI air source heat pump is specially designed for cold climate area, can best satisfy the household and commercial of sanitary hot water and floor heating use, it can work down to low temp of -25℃.

  • Branded componenets, heart compressor as top one America scroll Copeland, Japan saginomiya four way valve, Emerson expansion valve.

  • Environment friendly HCHF refrigerant  as R410A / R407C, 

  • Quick-mind LCD controller, one touch ON enjoy automate heating and hot water, timer ON/OFF function available.

  • Auxiliary electric heating control possible.

  • Intelligent defrosting technology, evaporator as finned tube heat excahnger with big air flow, its wave shape design efficiently reduced get frosting in winter, to the climate of dry air, adpoted “time + temp difference “defrosting control technology, defrosting in time and clean.

Technology changes life!
We concern your living feeling, also concern your electricity bill

Branded components

  • Mature design
    Adopt “Solkane 5.0” software to calculate heating, “Airsoft” software to calculate heat exchanger design, “system Design Simulator” to calculate cooling system capacity, to assure system match reasonable.

  • Reliable technology
    Nitrogen filled protection when welding, high pressure Nitrogen to keep pressure and electronic halogen detection for assure system no leaking.
    Pipe take shock absorber design, and take protector to assure pipe never get worn out.
    Wire lines atke insulation protection, assure never because of wire aging and get short circuit.

  • Reliable test
    Before delivery, unit has get through full test for safety, high temp, low temp, defrosting condition, assure unit run safely, stable and high efficient.

  • Suppress frosting and defrosting technology
    Supress frosting: Evaporator takes big air flow design, special allocate technology assure every refrigerant loop the same flow.
    Somre units adopt single row heat exchanger, improved heat exchange efficiency and decreased frosting form speed, adopt wave type high efficient fin, to assure frosting won’t block flow.
    Defrosting technology: Adopt PID defrosting technology of “time + temp difference change rate”, to assure defrosting in time and clean.

  • Refrigerant pressure control technology.
    Adopt patent produced refrigerant pressure buffer system, making the refrigerant system keep stable at different ambient temp and water temp.

Multiple models for chosen

CAR-12EVI side fan
CAR-20EVI CAR-24EVI side fan
CAR-12EVI CAR-20EVI up fan
CAR-24EVI/40EVI/60EVI/75EVI/80EVI
 Model  CAR-12EVI CAR-24EVI CAR-12EVI CAR-20EVI CAR-40EVI   CAR-60EVI CAR-75EVI CAR-80EVI
 Standard condition (Air source side DB/WB is 20℃/15℃, inlet water temp 15℃, outlet water temp 55℃.)
 Heating capacity KW  10.4  20.8  11.4  20.3  40.6   60.9  74.4 81.2
 Hot water output T/H  0.22  0.45  0.25  0.44  0.87   1.31  1.6  1.75
 Input power KW  2.58  5.12  2.77  4.8  9.6   14.4   16.3 19.2
 Low ambient temp condition (Air source side DB/WB is 7℃/6℃, inlet water temp 10℃ outlet water temp 55℃)  
 Heating capacity KW  8.65  17.3   9.59  16.6   33.2  49.8   62.7 66.4
 Hot water output T/H  0.17 0.33  0.18  0.32   0.63 0.95   1.2 1.27
 Input power KW  2.6 5.2  2.8  4.69   9.38 14.07   16.3 18.76
 Super low ambient temp condition Air source side DB/WB is -15℃/-17℃, inlet water temp 10℃, outlet water temp 55℃. )  
 Heating capacity KW  5.33 10.66   5.95  9.7   19.4  29.1   34.6 38.8
 Hot water output T/H  0.1  0.2   0.11  0.19   0.37  0.56   0.66 0.74
 Input power KW  2.5  5  2.7   4.15  9.3  14.45   15.6 19.6
 Power source  380V/3N/50HZ or 220V/1N/50HZ  380V/3N/50HZ
 Noise level dB(A)  <55   <58  <55  <58   <62  <64  <66  <66
 Unit weight Kg  115   175   115   145  270  470  620  620
 Unit size W x D x H cm                
 Up fan type  67x64x82  139x67x82  67x64x82  81x78x105  145x78x105  170x90x125  170x90x125  170x90x125
 Side fan type  88x37x100  130x42x125  88x37x100  112x43x126  /  /  /  /
 Connection pipe size DN  DN20  DN25  DN20  DN25  DN32  DN40  DN50  DN50
View full CAR-EVI series heat pumps parameter list pls click here.

More options for CAR-EVI air source heat pump

Stainless steel casing

Protect heat pump

Casing setting

Stainless steel casing is used to protect heat pump outcasing from rust install outside, the standard is galvanized steel casing with painting of white

Soft starter apparatus

Protect compressor

Adding on

With soft starter the machine will temporarily reduce the load and torque in the power train and electric current surge of the motor during start up.

Bottom heater

Protect heat pump

Adding on

Bottom heater is electrical tapes installed by heat pump bottom, when winter cold there water by the bottom, may start the bottom heater to avoid freeze.

Ask us for price and solutions today!