Hot water & heating 2018-05-03T08:44:45+00:00

Air source heat pump – heating & hot water
COP up to 4.7
work at -15℃ ambient temp
max outlet hot water temp +60℃

  • Compact structure and sound control design, no trouble to neighbours.

  • Branded componenets, heart compressor as top one America scroll Copeland, Japan saginomiya four way valve, Emerson expansion valve.

  • Environment friendly HCHF refrigerant  as R410A / R417A / R407C, 

  • Quick-mind LCD controller, one touch ON enjoy automate heating and hot water, timer ON/OFF function available.

  • Automatic anti-freeze function and defrosting control.

  • auxiliary electric heating control possible.

  • 220V/50HZ, 380V/50HZ, 440V/60HZ special power source is available.

Technology changes life!
We care your comfortable, also care your electricity bill

Branded components

  • Mature design
    Adopt “Solkane 5.0” software to calculate heating, “Airsoft” software to calculate heat exchanger design, “system Design Simulator” to calculate cooling system capacity, to assure system match reasonable.

  • Reliable technology
    Nitrogen filled protection when welding, high pressure Nitrogen to keep pressure and electronic halogen detection for assure system no leaking.
    Pipe take shock absorber design, and take protector to assure pipe never get worn out.
    Wire lines atke insulation protection, assure never because of wire aging and get short circuit.

  • Reliable test
    Before delivery, unit has get through full test for safety, high temp, low temp, defrosting condition, assure unit run safely, stable and high efficient.

  • Suppress frosting and defrosting technology
    Supress frosting: Evaporator takes big air flow design, special allocate technology assure every refrigerant loop the same flow.
    Somre units adopt single row heat exchanger, improved heat exchange efficiency and decreased frosting form speed, adopt wave type high efficient fin, to assure frosting won’t block flow.
    Defrosting technology: Adopt PID defrosting technology of “time + temp difference change rate”, to assure defrosting in time and clean.

  • Refrigerant pressure control technology.
    Adopt patent produced refrigerant pressure buffer system, making the refrigerant system keep stable at different ambient temp and water temp.

Multiple models for chosen

CAR-16XB CAR-20XB CAR-24XB side fan
CAR-12XB …CAR-28XB up fan
CAR-40XB … CAR-100XB
 Model  CAR-12XB CAR-14XB CAR-16XB  CAR-20XB  CAR-24XB   CAR-28XB  CAR-40XB  CAR-48XB  CAR-60XB CAR-80XB CAR-100XB
 Heating capacity KW 10.81 13  15  19  22  27.1  38  46.2  57.1  76  95
 Hot water output T/H  0.23  0.27  0.3  0.41   0.46   0.58   0.82  1  1.23   1.63   1.99 
 Input power KW  2.34  2.7  3.4  4.1  4.68   5.9   8.2   10.2  12.2  16.2   20.5
 Input current A  11.23/6.5  13.1/7.5  14/7.5  6.66  12  11  13.34  16  20  26.51  33.1 
 Power source  380V/3N/50HZ or 220V/1N/50HZ  380V/3N/50HZ
 Noise level dB(A)  <53    <53  <53   <55    <55  <60  <63  <64  <66  <68  <68
 Unit weight Kg  120   135  145    155  175   180   245  280  310  560   630 
 Unit size W x D x H cm                      
 Up fan type  67x64x82  67x64x82  81x78x105  81x78x105  88x78x105  88x78x105  145x78x105  145x78x120  145x78x140  170x90x125  180x101x125
 Side fan type  88x37x100  88x37x100  90x42x140  90x42x140  90x42x140  141x50x150  /  /  /  /  /
 Connection pipe size DN  DN20  DN20  DN25  DN25  DN25  DN32  DN32  DN32  DN40  DN50  DN50
 Test conditions:Air source side DB/WB is 20℃/15℃,initial hot water temp 15℃, ending hot water temp 55℃.
 View full CAR-XB series heat pumps parameter list pls click here.

More options for CAR-XB air source heat pump

Stainless steel casing

Protect heat pump

Casing setting

Stainless steel casing is used to protect heat pump outcasing from rust install outside, the standard is galvanized steel casing with painting of white

Soft starter apparatus

Protect compressor

Adding on

With soft starter the machine will temporarily reduce the load and torque in the power train and electric current surge of the motor during start up.

Bottom heater

Protect heat pump

Adding on

Bottom heater is electrical tapes installed by heat pump bottom, when winter cold there water by the bottom, may start the bottom heater to avoid freeze.

RS485 protocal

Technical adding

Adding on

RS485 protocal is a technology which can share information to the computer, clitech CAR-XB series heat pump can put this port.

Ask us for price and solutions today!
Your inquiry will be replied within 24 hours, and we value your privacy.

Contact us